Offices, Clinics & Retail Showrooms

Keeps computers, diagnostic equipment and air conditioning running through the voltage swings common on commercial supply lines.

Power to Protect

Quick Installation

Genuine Spare Parts

Pan-India Service Network

Offices, clinics and retail showrooms all run on the same low-tension commercial supply, and it swings the same way it does everywhere else on the grid – dropping through the afternoon as load builds, climbing back up once most connections switch off for the night. A desktop that restarts mid-invoice, a diagnostic machine drifting out of calibration, a POS terminal locking up mid-sale: none of these look like a power problem until the pattern repeats often enough to notice. Split ACs are usually the first thing to fail outright, since a compressor drawing its starting current on a low line either trips the unit or strains its motor windings.

Bluebird’s Automatic Voltage Stabilizer covers this at two points. A main line unit fitted at the distribution panel protects everything downstream from a single connection – computers, EPABX, billing systems, lighting – sized between 0.5 KVA and 10 KVA depending on the space. Where the AC load needs its own protection, a dedicated AC stabilizer sits on the compressor circuit and corrects fast enough to keep up with its start-up draw. Both switch correction electronically rather than through a motor, so there’s close to no delay, and both are tested to IS:8448:1989. A showroom or clinic that outgrows this range – a larger floor, a diagnostic centre running heavier imaging equipment – moves up to Bluebird’s Servo Voltage Stabilizer line, which scales to 1500 KVA.

Electronic Tap-Switching

Corrects voltage by switching transformer taps electronically, not with a motor, so the correction is close to instant.

Sized for Compressor Start-Up

Rated to handle the surge an AC compressor draws when it starts, not just its running current.

Main Line or Per-Unit Protection

A main line unit protects the whole panel from one point; a dedicated AC stabilizer protects a single split or window unit.

Voltage Display

Shows input and output voltage on most models, so a developing fault is visible before it causes a breakdown.

Tested to IS:8448:1989

Every unit is tested to this specification before it leaves the factory.

Scales Beyond 10 KVA

A larger office floor or multi-room clinic moves up to Bluebird's Servo Voltage Stabilizer line, rated to 1500 KVA.

Applicable Products

Know What You Need, or Want Our Recommendation?

Enquire about any of these stabilizers, or let our team help you pick the right one.

Help Me Choose